Rohde & Schwarz URE3
Main Features and
Specifications

 Check Price for :
 
 Sell Yours!
 
Order
manual
 
Page  1  
$
Price
 Rohde & Schwarz URE3 30MHz RMS/Peak Voltmeter - IN STOCK!!   UK  
  Rohde & Schwarz URE3 DC, 30mHz-30MHz RMS Voltmeter   IE $ 4,200 
  Rohde & Schwarz URE3 Peak Voltmeter   US  
 Rohde and Schwarz URE3 REFURBISHED VOLTMETER (R&S) 0.02Hz-30MHz US $ 5,600 
  Rohde Schwarz URE3 NEW EQUIPMENT! Characteristics RMS/Peak Voltmeter     New EQ. US $ 6,740 
  Rohde & Schwarz URE3 Peak/RMS Power Meter Refurbished, Guaranteed to US  
  Rohde & Schwarz URE3 Peak/RMS Power Meter   US  
  Rohde&Schwarz URE3   DE $ 2,902 
 Rohde and Schwarz URE3 dc, 30mHz-30MHz RMS/Peak Voltmeter รบ 1950 UK  
 
 
 
  Rohde & Schwarz URE3 : Main Features and Specifications
Rohde & Schwarz URE3  
 
Low end frequency limit  20 mHz 
High end frequency limit  30.0 MHz 
Voltage Range Low  50 uV
Voltage Range High  300 V
Status new
Launch Date
--
Discontinued on --
Supported until --
See also URE2
 
  Rohde & Schwarz URE3 Specs (815.6 KB)
 
Rohde & Schwarz URE3 Features :

A  patented rectifier circuit with microprocessor-controlled autocalibration makes for the outstanding measurement characteristics of URE2 and URE3.
In order to further enhance the accuracy, correction factors are determined for each instrument and measurement range and stored in a nonvolatile memory.


A zero function allows noise voltages and the inherent noise to be compensated for, the measurement accuracy being thus increased in particular at low levels.


The measured frequency value is used by URE3 for an internal frequency response correction.
This method increases the accuracy mainly at the higher frequencies.



  • True RMS weighting for AC and AC + DC

  • More than 30 measurements/s

  • 4.5-digit display and analog display with selectable scale

  • Very high measurement accuracy

  • Highpass and lowpass filters

  • Relative measurement, maxima/ minima

  • Convenient menu-guided operation

  • Use of commercial probes, taking into account their division factor in the displayed result

  • IEC bus (IEEE488)

  • Peak-value measurement (positive, negative, peak-to-peak) without tilts and overshoots

  • Fast RMS measurement even of very low-frequency signals

  • Frequency measurement up to 30 MHz

  • Ultrahigh measurement accuracy through automatic frequency response correction

  • In/out option: dual-channel analog output, ready output, trigger input, TTL frequency counter input