Dual Output Mobile Communications DC Source
0 - 15 V / 0 - 3 A / 5 A Peak
The Agilent (now Keysight) 66319B is a Dual Output Mobile Communications DC Source w/ Battery Emulation and ideal for testing wireless and battery powered devices.
It provides two outputs for testing both the main battery power and the battery charger circuitry, allowing customers to test phones and chargers with the same equipment. This feature helps save on rack space (2 outputs in a ½ rack box) and eliminates the need for two separate power supplies.
Number of outputs: 2
Output rating:
Voltage: 0 to 15 V
Current: 0 to 3 A
Current peak: 5 A (for up to 7 ms)
Programming accuracy:
Voltage: 10 mV
+Current: 1.33 mA
DC measurement accuracy (voltage): 0.03% + 5 mV
Dynamic measurement system (buffer size): 4096 points
Programmable output resistance: -40 mOhm to +1 Ohm
Resolution: 1 mOhm
Auxilary output: 0 to 12 V an 0 to 1.5 A
Transient response:
40 mV drop, <20 ms transient response time
Fast output response Technology
Programmable output Response compensation
Advanced DSP-based dynamic measurements
Current sinking for testing and calibrating charger circuitry
Extensive protection Features (incl. broken sense lead detection)
GPIB Interface, SCPI (Standard Commands for Programmable Instruments), VXIplug&play Drivers
High performance:
Output resistance programming (positive and negative)
Superior output stability with up to 6 meters of load leads
Excellent transient voltage drop (typ. <30 mV)
Three current measurement ranges
Additional advanced battery drain measurements (CCDF, long
term battery drain)
€ 1,390 $1,668 (US)