Condition: Used
Warranty: 90 day with onsite installation. Other options available upon request.
Test Performed: tested
Listing ID# 105
Agilent 1100 Capillary Pump (G1376A)
This Agilent 1100 Series G1376A ( G1376 A / G 1376 A / G 1376A ) Capillary Pump ( Cap Pump) is in excellent condition.
This system, based on the reliable Agilent 1100 Series HPLC system, uses a unique pump technology that optimizes the system for capillary LC, offering a high level of sensitivity and reproducibility.
The Agilent 1100 Series capillary pump incorporates an electronic flow control (EFC) that measures and controls the actual flow rate, rather than depending on calculations. This assures flow rate stability throughout the analysis. The pump provides flow rates from 1µl/min up to 100µl/min, with full gradient capability for capillary LC and 2.5ml/min in normal mode for a wide range of flexibility.
A unique pump design offers better control and flexibility of low flow rates. This pump is ideally suited for capillary LC and LC/MS applications, like bio-pharmaceutical research, where sample volumes are limited and higher sensitivity is essential.
Features:
- Electronic flow control (EFC) – measures and controls the actual flow rate, rather than depending on calculations.
- Flow rates – from 1 µl/min up to 100 µl/min, with full gradient capability for capillary LC and 2.5 ml min in standard mode for a wide range of flexibility
- Retention time (RT) stability – independent from column back pressure for maximum performance
- Accurate flow rates – even with solvent mixtures
- Automatic purge valve
- Low delay volume– through the use of microvolume components
Specifications:
Type | Specification |
Hydraulic system | Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates up to 100 µl/min |
Settable column flow Range | 0.01 – 20 µl/min 0.01 – 100 µl/min (with the extended flow range kit) 0.001 – 2.5 µl/min (with the electronic flow control bypassed) |
Recommended column flow range | 1 – 20 µl/min 10 – 100 µl/min (with extended flow range kit) 0.1 – 2.5 ml/min (with the electronic flow sensor bypassed) |
Column flow precision | < 0.7 % RSD or 0.03 % SD (typically 0.4 % RSD or 0.02 % SD), at 10 µl/min and 50 µl/min column flow (based on RT, default setting) |
Optimum composition Range | 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater |
Composition precision | < 0.2 % SD, at 10 µl/min (20 µl flow sensor), 50 µl/min (100 µl flow sensor) and 1 ml/min (normal mode) default setting |
Delay volume | Typically 3 µl from the electronic flow control to the pump outlet for flow rates up to 20 µl/min. Typically 12 µl from the electronic flow control to the pump outlet for flow rates up to 100 µl. for flow rates up to 100 µl/min and electronic flow control active: primary flow path 180 – 480 µl without mixer, 600 – 900 µl with mixer (system pressure dependent) Typically 180 to 480 µl (system pressure dependent) without mixer for flow rates up to 2.5 ml/min. (Mixer delay volume 420 µl) |
Pressure range | 20 to 400 bar (5880psi) system pressure |
Compressibility Compensation | User-selectable, based on mobile phase compressibility |
Recommended pH Range | 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries. |
Control and data Evaluation | Agilent ChemStation for LC |
Analog output | For pressure monitoring, 2 mV/bar, one output |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors. |
Housing | All materials recyclable |
Please note: Licenses for Agilent´s software products are not transferable. Any customer who purchases Agilent products are advised to contact Agilent for license requirements.
All Brand Names and Logos depicted at our website are the trademarks of the respective companies. We are not their representative nor authorized resellers.
We have extensive experience with Agilent Chromatography systems. We carry a large inventory of Agilent/HP components and full systems and you are able to customize your system with other configurations if needed. Upon purchase, support will be available via phone, email, or Skype.