Condition: New
Fluke 190-102-III-S 100 MHz 2-Channel ScopeMeter Test Tool with SCC-293 Kit
Key Features At A Glance
- CAT III 1000 V / CAT IV 600 V safety rating for industrial environments with up to four independent floating isolated inputs
- Bandwidth options from 60 MHz to 500 MHz across two-channel and four-channel models
- Real-time sample rates up to 5 GS/s and 10,000 samples per channel deep memory in scope mode
- Connect-and-View triggering automatically displays stable waveforms of complex and dynamic signals without manual setup
- ScopeRecord mode captures 30,000 points per channel with 8 ns glitch capture for low-frequency signal analysis
- TrendPlot paperless recorder logs up to four readings with date and time stamp for intermittent fault diagnosis
- Automatic capture and replay of the last 100 screens with date and time stamp on each screen
- IP51 rated sealed case with rugged shock-proof design and up to seven hours of battery operation using BP291
View full details
The Fluke 190 Series III ScopeMeter is a family of handheld portable oscilloscopes engineered for field measurement work in industrial environments. The series spans seven models, available in two-channel and four-channel configurations with bandwidth options of 60 MHz, 100 MHz, 200 MHz, and 500 MHz. Each unit combines the performance of a bench oscilloscope with the portability and safety isolation needed for work outside the laboratory, with independently isolated inputs that reduce the risk of accidental short circuits when measuring across mixed-ground-reference circuits.
Applications named on the datasheet include installation, commissioning, and maintenance of industrial machinery, automation and process controls, and power conversion electronics. The ScopeRecord mode is specifically positioned for recording events such as UPS, power supply, and motor start-up cycles, with the Stop on Trigger mode set up to recognize a power failure and store the waveform data preceding it. The TrendPlot paperless recorder is positioned for finding intermittent faults caused by bad connections, dust, dirt, corrosion, broken wiring, line outages, dips, swells, interruptions, and motor start-stop events.
ValueTronics has supported test and measurement professionals since 1992 from our 20,000 sq ft secure warehouse at 1675 Cambridge Drive in Elgin, Illinois. Every Fluke 190 Series III ScopeMeter that passes through our facility is inventoried, inspected, and prepared for shipment by our in-house team rather than drop-shipped from a third party. That model lets us answer specific questions about a unit before it ships, confirm what is and is not included with a given configuration, and stand behind what we send.
Brand Heritage
Fluke Corporation has manufactured handheld test instruments since 1948 and has operated as a subsidiary of Fortive Corporation since the 2016 spinoff of Fortive from Danaher Corporation. Fluke acquired Philips Test & Measurement's portable instrument lines in 1993, which is part of the heritage behind the ScopeMeter handheld oscilloscope category.
Compare Other Models in This Series
The Fluke 190 Series III ScopeMeter family is built around a common platform — shared safety rating, shared display, shared trigger architecture, shared connectivity, and shared software ecosystem — with seven configurations that scale bandwidth, channel count, and sample rate to match the measurement work. Every model in the series carries the CAT III 1000 V / CAT IV 600 V safety rating, the IP51 environmental rating, the 133 mm by 90 mm color LCD, the dual USB ports, and the Connect-and-View triggering engine. What differs between models is bandwidth, channel count, sample rate, included probe type, included battery, and the presence or absence of the built-in 5,000 count digital multimeter.
Two-channel models in the series (190-062, 190-102, 190-202, 190-502) include a built-in DMM accessed through dedicated 4 mm banana inputs that are fully isolated from the scope inputs and scope ground, plus an external trigger input. Four-channel models (190-104, 190-204, 190-504) provide four BNC scope inputs and surface multimeter-style readings as automatic scope measurements through those inputs rather than through a separate DMM section.
Each new model in the series is listed on its own dedicated product page with condition-matched pricing. Use the per-model pages linked below to confirm bandwidth, channel count, included probes, included battery, and any specific accessory bundle on the unit you are evaluating.
Bandwidth and sample rate scale together across the series. The 60 MHz two-channel 190-062 samples at 625 MS/s per channel; the 100 MHz models (190-102, 190-104) sample at 1.25 GS/s per channel; the 200 MHz models (190-202, 190-204) sample at 2.5 GS/s per channel; the 500 MHz models (190-502, 190-504) reach 5 GS/s on a single channel and divide that capability across active channels as more inputs are turned on. Rise time follows the same scaling, from 5.8 ns at 60 MHz down to 0.7 ns at 500 MHz.
Channel-count and DMM features also drive selection. The two-channel configurations carry the standalone 5,000 count DMM with a 30 MΩ resistance range and Vdc accuracy of plus or minus 0.5 percent plus 6 counts; the four-channel configurations trade the standalone DMM section for two additional fully isolated scope channels and surface measurements through the BNC inputs at plus or minus 999 counts (9999 counts for frequency). Included probe type and included battery also vary across the series — see the comparison table that follows for the full per-model breakdown.
| Model |
Bandwidth |
Channels |
Max Sample Rate |
| 190-102-III-S |
100 MHz |
2 |
1.25 GS/s |
| 190-062-III |
60 MHz |
2 |
625 MS/s |
| 190-102-III |
100 MHz |
2 |
1.25 GS/s |
| 190-202-III |
200 MHz |
2 |
2.5 GS/s |
Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.
Accessories Supplied
- All standard 190-102-III accessories
- SCC293 kit: CXT293 rugged protective carrying case
- SCC293 kit: full-version FlukeView PC software (activation code)
- SCC293 kit: WiFi dongle for wireless PC connectivity
Product Core & Specifications
| Specification |
Value |
| Input coupling |
AC or DC, with ground level indicator |
| Input sensitivity |
With 10:1 probe: 20 mV to 1000 V/div; With 100:1 probe: 200 mV to 10 kV/div; Direct (1:1): 2 mV to 100 V/div |
| Bandwidth limiter |
20 MHz and 10 kHz |
| Polarity |
Normal, Inverted, Variable |
| Channel architecture |
All inputs fully insulated from each other and from ground. Inputs may be activated in any combination |
| Vertical resolution |
8 bit |
| Accuracy at 4 s to 10 μs/div |
5 mV/div to 100 V/div: ±(1.5 % + 6 counts); 2 mV/div: ±(1.5 % + 10 counts) |
| Input impedance |
1 MΩ (± 1 %) // 15 pF (± 2.25 pF) |
| Rated maximum floating voltage |
CAT III 1000 V / CAT IV 600 V |
| Probe input voltage VPS410-II |
CAT III 1000 V / CAT IV 600 V |
| Probe input voltage VPS421 |
CAT III 1000V / CAT IV 600V (2000V max between probe tip and reference lead) |
| Maximum BNC input voltage |
CAT IV 300 V |
| Record length (scope mode) |
Up to 10,000 samples per channel |
| ScopeRecord roll mode memory |
30,000 data points per channel |
| ScopeRecord recorded timespan |
4.8 sec to 40 hr |
| TrendPlot memory depth |
19,200 points (sets) per recording |
| TrendPlot recorded time span |
Up to 22 days (resolution 102 sec); up to 5.5 days for 4 readings |
| Display |
133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD |
| Resolution |
1120 pixels x 765 pixels |
| Brightness |
User-adjustable, up to 300 cd/m² |
| Digital persistence modes |
Off, short, medium, long, infinite and envelope mode |
| Acquisition modes |
Normal, Averaged, Auto, Single Shot, ScopeRecord roll, glitch capture, waveform compare with Pass/Fail testing, Replay |
| Replay |
Automatic capture of last 100 screens; manual or continuous replay with date and time stamp |
| FFT window |
Automatic, Hamming, Hanning or None |
| Memory locations (internal) |
30 waveform memories, 10 recording memories, 9 screen copy memories |
| External data storage |
USB flash memory drive up to 32 GB or PC via FlukeView-2 |
| Case design |
Rugged, shock-proof with integrated protective holster; Kensington lock supported |
| Drip and dust proof |
IP 51 according to IEC60529 |
| Shock and vibration |
Shock 30 g, vibration (sinusoidal) 3 g / 0.03 g²/Hz (Random), per MIL-PRF-28800F Class 2 |
| Size |
265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in) |
| Line power |
Universal mains adapter/battery charger BC190/830, 100 Vac to 240 Vac, ±10 %, 50-60 Hz |
| Safety compliance |
EN61010-1, Pollution Degree 2; IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V |
| Operating temperature |
0 °C to 40 °C (32 °F to 104 °F) |
| Storage temperature |
-20 °C to 60 °C (-4 °F to 140 °F) |
| Maximum operating altitude |
CAT IV 600 V, CAT III 1000 V: up to 2000 m (6,600 ft); CAT IV 300 V, CAT III 600 V, CAT II 1000 V: up to 4000 m (13,000 ft) |
| Maximum storage altitude |
12 km (40,000 ft) |
| EMC |
IEC 61326-1: Industrial; CISPR 11: Group 1, Class A; USA (FCC): 47 CFR 15 subpart C |
| Interfaces |
Two USB ports (USB-A host + mini-USB-B), fully insulated from measurement circuitry; optional WiFi adapter |
| Probe calibration output |
1.225 Vpp / 500 Hz square wave, fully insulated from measurement input channels |
| Warranty |
3 years on main instrument, 1 year on battery and accessories |
Important: Maximum BNC input voltage is CAT IV 300 V when measuring directly through the BNC input. Maximum rated floating voltage of CAT III 1000 V / CAT IV 600 V applies between any contact and earth-ground voltage level when using the supplied voltage probes (VPS410-II 10:1 or VPS421 100:1).
Important: All inputs are fully insulated from each other and from ground, providing CAT III 1000 V / CAT IV 600 V rated floating isolated inputs for safe measurement in mixed-reference circuits.
Important: The 190-104-III, 190-204-III and 190-504-III (4-channel models) do not include a separate banana-input DMM; meter measurements on these models are performed via the BNC scope inputs as automatic scope measurements.
Important: Battery charging and discharging are specified within 0 °C to 40 °C (32 °F to 104 °F). Operating outside this range may reduce specified accuracy by 10 % per degree C below 18 °C or above 28 °C.
Important: Each model is also available in a '-S' configuration that includes the SCC293 kit (CXT293 rugged carrying case, full-version FlukeView-2 PC software activation, and a WiFi dongle for wireless PC connectivity).
Recommended pairing: the VPS421 100:1 ruggedized industrial-grade probes (150 MHz) ship standard with the 60 MHz and 100 MHz two-channel and 100 MHz four-channel configurations for higher-voltage work; the VPS410-II 10:1 probes (500 MHz) ship with the 200 MHz and 500 MHz configurations. Replacement and color-coded sets are listed on the datasheet for both probe families.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.