BrandModelModelUrlStatusFreq. Resolution [Digits]Max. Freq.MeasurementsMin. Freq.
BK Precision106/list-counters/timer/bk-precision-106Disc{ "specId": "36", "unit": "", "controlType": "3", "value": "7", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "2800000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "30000000", "colIndex": "7", "specName": "Min. Freq." }
TektronixDC5009/list-counters/timer/tektronix-dc5009Disc{ "specId": "36", "unit": "", "controlType": "3", "value": "8", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "1300000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Count totalization, Event, Pulse width", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "1", "colIndex": "7", "specName": "Min. Freq." }
FlukePM 6690/list-counters/timer/fluke-pm-6690Disc{ "specId": "36", "unit": "", "controlType": "3", "value": "12", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "8000000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Time interval, Rise/Fall Time, Duty factor, Pulse width, Voltage, Burst freq.", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "0.001", "colIndex": "7", "specName": "Min. Freq." }
Fluke1952B/list-counters/timer/fluke-1952bDisc{ "specId": "36", "unit": "", "controlType": "3", "value": "7", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "80000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Time interval", "colIndex": "6", "specName": "Measurements" }
TektronixFCA3000/list-counters/timer/tektronix-fca3000{ "specId": "36", "unit": "", "controlType": "3", "value": "12", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "300000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Time interval, Rise/Fall Time, Duty factor, Pulse width, Voltage, True RMS", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "0.001", "colIndex": "7", "specName": "Min. Freq." }
TektronixFCA3003/list-counters/timer/tektronix-fca3003{ "specId": "36", "unit": "", "controlType": "3", "value": "12", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "3000000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Time interval, Rise/Fall Time, Duty factor, Pulse width, Voltage, True RMS", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "0.001", "colIndex": "7", "specName": "Min. Freq." }
TektronixFCA3020/list-counters/timer/tektronix-fca3020{ "specId": "36", "unit": "", "controlType": "3", "value": "12", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "20000000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Time interval, Rise/Fall Time, Duty factor, Pulse width, Voltage, Burst freq., True RMS", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "0.001", "colIndex": "7", "specName": "Min. Freq." }
TektronixFCA3100/list-counters/timer/tektronix-fca3100{ "specId": "36", "unit": "", "controlType": "3", "value": "12", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "300000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Count totalization, Time interval, Rise/Fall Time, Duty factor, Pulse width, Voltage, True RMS", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "0.001", "colIndex": "7", "specName": "Min. Freq." }
TektronixFCA3103/list-counters/timer/tektronix-fca3103{ "specId": "36", "unit": "", "controlType": "3", "value": "12", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "3000000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Count totalization, Time interval, Rise/Fall Time, Duty factor, Pulse width, Voltage, True RMS", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "0.001", "colIndex": "7", "specName": "Min. Freq." }
TektronixFCA3120/list-counters/timer/tektronix-fca3120{ "specId": "36", "unit": "", "controlType": "3", "value": "12", "colIndex": "4", "specName": "Freq. Resolution [Digits]" }{ "specId": "69", "unit": "Hz", "controlType": "2", "value": "20000000000", "colIndex": "5", "specName": "Max. Freq." }{ "specId": "87", "unit": "", "controlType": "1", "value": "Frequency, Period, Ratio, Count totalization, Time interval, Rise/Fall Time, Duty factor, Pulse width, Voltage, Burst freq., True RMS", "colIndex": "6", "specName": "Measurements" }{ "specId": "92", "unit": "Hz", "controlType": "2", "value": "0.001", "colIndex": "7", "specName": "Min. Freq." }