Leader LS8106A

Price : Call
  •  Equipment Location : USA
Description:
LS8106A Top of the line Leader LS 8106A offers speed and operating shortcuts found in very few modern scopes. Examples include Auto Setup in which a single touch automatically sets both V sensitivity and timebase for instant, optimum waveform display. Another great convenience is a continuous on-screen readout of the operator choice of frequency or period and Vp-p or DC level for signals handled in CH1. One-Touch Auto Setup Sets V Sensitivity and Time Base Continuous On-Screen Readout of Frequency and Vp-p or DC Level for CH1 On-Screen Readout of H&V Scale Factors, Coupling, Uncal, INVert, ADD, MAG, X- Y and Delay Line Cursor Measurements of (DV, DT, DV%,DT%, 1/DT ) Frequency and Phase 100-MHz Bandwidth Calibrated Delayed Sweep Alternate Sweep - Shows Main and Delayed Waveforms Simultaneously 3-Channel, 8-Trace Operation CH1, CH2, CH3, CH1 + CH2 Main and Delayed 400 V (dc ?} ac peak) Input Withstand (CH1 and CH2) FIXed Trigger Mode Ensures Stable Triggering Despite Wide Amplitude Swings Dedicated TV-V and TV-H Sync Separators for Rock Solid Video Waveforms Variable Holdoff for Correct Display of Complex Wavetrains Single Sweep Operation X-Y Operation 2% V Accuracy 1 mV/div Sensitivity with 20-MHz Band Limit 5 ns/div Sweep Speed with X10 Mag Signal Delay (All Channels) Ensures View of Trigger Edges CH1 Output Makes CH1 Amplifier Available as a High Gain Calibrated Preamp Z-Axis (Intensity Modulation) å reconditioned

PRODUCT SPECS

(From Used-Line T&M Specifications )
  Leader LS8106A Specs (183.9 KB)
Status Discontinued
Alternative No replacement
See also LS8106

Top of the line Leader LS 8106A offers speed and operating shortcuts found in very few modern scopes. Examples include Auto Setup in which a single touch automatically sets both V sensitivity and timebase for instant, optimum waveform display. Another great convenience is a continuous on-screen readout of the operator choice of frequency or period and Vp-p or DC level for signals handled in CH1.

  • One-Touch Auto Setup Sets V Sensitivity and Time Base
  • Continuous On-Screen Readout of Frequency and Vp-p or DC Level for CH1
  • On-Screen Readout of H&V Scale Factors, Coupling, Uncal, INVert, ADD, MAG, X-
  • Y and Delay Line
  • Cursor Measurements of (DV, DT, DV%,DT%, 1/DT )
  • Frequency and Phase 100-MHz Bandwidth
  • Calibrated Delayed Sweep
  • Alternate Sweep - Shows Main and Delayed Waveforms Simultaneously
  • 3-Channel, 8-Trace Operation CH1, CH2, CH3,
  • CH1 + CH2 Main and Delayed
  • 400 V (dc ?} ac peak) Input Withstand (CH1 and CH2)
  • FIXed Trigger Mode Ensures Stable Triggering Despite Wide Amplitude Swings
  • Dedicated TV-V and TV-H Sync Separators for Rock
  • Solid Video Waveforms
  • Variable Holdoff for Correct Display of Complex Wavetrains
  • Single Sweep Operation
  • X-Y Operation
  • 2% V Accuracy
  • 1 mV/div Sensitivity with 20-MHz Band Limit
  • 5 ns/div Sweep Speed with X10 Mag
  • Signal Delay (All Channels) Ensures View of Trigger Edges
  • CH1 Output Makes CH1 Amplifier Available as a High Gain Calibrated Preamp
  • Z-Axis (Intensity Modulation)

 

CONTACT THE SELLER (RFQ)


To:  Recon Test Equipment Inc
 
All fields are required
 Remember me
 Send me a copy.
Send
News, sales, & auction announcements
About the Seller
since 2010



Recon Test Equipment Inc


831
Visitors viewed Recon Test Equipment Inc ads in the last 30 Days.


The dealer's latest update: over 30 days


720-B Palmetto St New Smyrna Beach 32168 FL USA  
More about this seller »


Sales Conditions:

All equipment is offered with a parts and labor warranty and right of refusal period to give you the added assurance you are receiving quality equipment ready to work upon a timely delivery.

Some of the services we offer:

(Rentals) (Calibration) (Repair)

Similar Listings: